Skip to main content

FlameLine FlameLine Fixed Glazing

Technical information

Performance

Energy

Thermal insulation - Ud
0.83 W/m²K

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class E1050 (1050Pa)
Wind load resistance
Class C4 (1600Pa)

Safety

Burglar resistance
RC2
Fire resistance
EI 30 - EI 60
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
4000 mm
Max. weight of fixed vent
400 kg

Sightlines

Min. frame width (inward opening)
74 mm
Min. vent width (inward opening)
74.5 mm
Min. frame-vent width (inward opening)
154.5 mm
Min. frame width (outward opening)
48 mm
Min. vent width (outward opening)
100.5 mm
Min. frame-vent width (outward opening)
154.5 mm
Min. width T-profile
106 mm
Depth frame
85 mm
Depth Vent
85 mm
Depth frame-vent
85 mm