MasterLine 10 Functional
Technical informationPerformance
Energy
- Thermal insulation - Uf
 - 0.99 W/m²K
 - Uw Dependencies
 - Single inward opening door: Ug 0.6W/m²K, warm edge spacer,@1.23x2.18m, 48mm glass
 - Thermal insulation - Ud
 - 0.82 W/m²K
 
Comfort
- Air tightness
 - Class 4 (600Pa)
 - Water tightness
 - Class 9A (600Pa)
 - Wind load resistance
 - Class C3 (1200Pa)
 - Acoustics - Rw(C;Ctr)
 - 40(-1;-3) dB
 - Opening & closing resistance
 - Class 8
 
Safety
- Burglar resistance
 - RC2
 - Impact resistance
 - I5 - E5
 
Properties
Max. dimensions & weight
- Max. height of vent
 - 3000 mm
 - Min. width of vent
 - 500 mm
 - Max. width of vent
 - 1400 mm
 - Max. weight of vent
 - 250 kg
 
Sightlines
- Min. frame width (inward opening)
 - 83.5 mm
 - Min. vent width (inward opening)
 - 71.5 mm
 - Min. frame-vent width (inward opening)
 - 155 mm
 - Min. frame width (outward opening)
 - 44.5 mm
 - Min. vent width (outward opening)
 - 110.5 mm
 - Min. frame-vent width (outward opening)
 - 155 mm
 - Min. width T-profile
 - 87 mm
 - Min. height treshold
 - 0 mm
 - Depth frame
 - 97 mm
 - Depth Vent
 - 107 mm
 - Depth frame-vent
 - 97 mm
 
Glazing
- Rebate height
 - 27 mm
 - Glazing method
 - Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
 - Min. glass thickness - frame/element
 - 20 mm
 - Max. glass thickness - frame/element
 - 78 mm
 - Min. glass thickness - vent
 - 30 mm
 - Max. glass thickness - vent
 - 88 mm