ConceptWall 50 Transom Transom
Technical informationPerformance
Energy
- Thermal insulation - Ucw
 - 0.56 W/m²K
 
Comfort
- Air tightness
 - AE 1200 (1200Pa)
 - Water tightness
 - RE1200 (1200 Pa)
 - Wind load resistance
 - Class A5 (2000Pa)
 - Acoustics - Rw(C;Ctr)
 - 47(-2;-5) dB
 
Safety
- Burglar resistance
 - RC2 - RC3
 - Impact resistance
 - I5 - E5
 
Properties
Max. dimensions & weight
- Min. height of vent
 - 600 mm
 - Min. width of vent
 - 450 mm
 - Max. weight of vent
 - 180 kg
 - Min. intertia mullion - Ix
 - 74 cm4
 - Max. intertia transom - Ix
 - 937 cm4
 - Min. intertia transom - Iy (glass load)
 - 23 cm4
 - Max. intertia transom - Iy (glass load)
 - 68 cm4
 
Sightlines
- Min. width T-profile
 - 50 mm
 - Min. visible width (interior view)
 - 50 mm
 - Min. visible width (exterior view)
 - 50 mm
 - Min. depth mullion
 - 83.5 mm
 - Max. depth mullion
 - 230.5 mm
 - Min. depth transom
 - 83.5 mm
 
Glazing
- Rebate height
 - 20 mm
 - Glazing method
 - Dry glazing - Siliconized glazing - Pressure plate glazing
 - Min. glass thickness - frame/element
 - 8 mm
 - Max. glass thickness - frame/element
 - 64 mm