Performance

Comfort

Air tightness
AE1200 (1200Pa)
Water tightness
RE1200 (1200Pa)
Wind load resistance
2400 Pa
CWCT tested according to
Sequence B
Air Leakage CWCT
A4 (600Pa)
Water Penetration CWCT
R7 (600Pa)
Wind Resistance (Serviceability) CWCT
2400 Pa
Wind Resistance (Safety) CWCT
3600 Pa
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. intertia mullion - Ix
195 cm4
Max. intertia mullion - Ix
418 cm4
Min. intertia transom - Ix
302 cm4
Max. intertia transom - Iy (glass load)
712 cm4

Sightlines

Min. width T-profile
75 mm
Min. visible width (interior view)
75 mm
Min. visible width (exterior view)
75 mm

Glazing

Glazing method
Dry glazing