Skip to main content

ConceptSystem 77 Hidden Vent

Technical information

Performance

Energy

Thermal insulation - Uf
2.1 W/m²K
Thermal insulation - Uw
1.4 W/m²K
Uw Dependencies
Frame-vent: Ug 1.0W/m²K, warm edge spacer, @1.23x1.48m (104mm sight line), 36mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class E750 (750Pa)
Wind load resistance
Class C4 (1600Pa)
Acoustics - Rw(C;Ctr)
46(-1;-4) dB
Opening & closing resistance
Class 3

Safety

Burglar resistance
RC2 - PAS 24
* Note: Performances and properties may be different depending on the profile combinations

Properties

Sightlines

Min. frame width (inward opening)
76 mm
Min. vent width (inward opening)
0 mm
Min. frame-vent width (inward opening)
76 mm
Depth frame
68 mm
Depth Vent
72.5 mm
Depth frame-vent
77 mm

Glazing

Rebate height
18.5 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead
Min. glass thickness - vent
21 mm
Max. glass thickness - vent
48 mm